Vacuum Ceramic Relay JPK-2/Type 009/054

Vacuum relay is a kind of electronic equipment that uses vacuum tube as the control element. It has unique working principle and remarkable characteristics, and is widely used in various circuits.

Category: Vacuum relay

key word : Vacuum Ceramic Relay JPK-2/Type 009/054


Specification No. JPK-2/009 JPK-2/054
Contact combination form 1Z 1Z
Test voltage (DC or 50Hz AC peak) kV 15 15
Rated operating voltage (peak) kV DC or AC 50Hz 12 12
AC2.5MHz 10  
AC16MHz 8  
AC32MHz 5  
Rated carrying current (effective value) A DC or AC 50Hz 50 30
AC2.5MHz 30  
AC16MHz 17.5  
AC32MHz 10  
Contact resistance (max.) Ω 0.012 0.025
Distributed capacitance (pf) Disconnected shock room 0.5 0.5
Between electric shock and enclosure 1 1
Insulation resistance (minimum) MΩ Disconnected shock room 10000 10000
Between coil and housing 1000 1000
Action time (max.) ms 18 18
Release time (max) ms 9 9
Temperature range (℃) -55~ 125 -55~ 125
Impact level (Peak g's) 50 50
Vibration level (Hz) 10~500 10~500
Mechanical life (× 106) 1 1
Nominal weight (g) 74 74

Coil Data

Nominal voltage (DC) V 220 110 48 27 24 12
pull-in voltage (Max) V 150 70 30 16 16 8
Release voltage (Minimum) V 10 2 2 1.5 1.5 0.5
Coil resistance Ω ± 10% 10000 5400 615 270 180 48

 